Dry Heat Biological Indicator

SteriVision Dry Heat Biological Indicator is designed to provide microbiological verification of dry heat sterilization cycles used in healthcare, laboratory, and industrial settings. The self-contained indicators can be positioned directly among loads, inside packs, or at locations considered most difficult for heat to reach. Their robust glass ampoule and protective plastic vial construction helps maintain integrity throughout processing while providing clear evidence that the required time and temperature conditions have been achieved.

SteriVision Dry Heat Biological Indicator packaging and self-contained indicator vials

Each indicator contains viable Bacillus atrophaeus (ATCC 9372) spores, selected for their high resistance to dry heat. After exposure, the internal ampoule is activated and the indicator is incubated for 48 hours. A visible color response in the growth medium indicates whether microbial growth is present, enabling personnel to distinguish a successful cycle from a potential sterilization failure and document the result with confidence.

Key Benefits and Features

1
Direct Load Placement

Place the indicator directly inside the dry heat sterilizer, between instruments or packs, and at the most challenging points of the load without disrupting routine workflow.

2
Biological Verification

Highly resistant Bacillus atrophaeus spores provide direct microbiological evidence of the cycle’s ability to inactivate resistant microorganisms.

3
Clear Results After 48 Hours

Following 48 hours of incubation, the color of the growth medium provides an easy-to-interpret indication of cycle performance.

No Growth — Cycle Successful
Growth Detected — Cycle Failed

Reliability and Traceability

Complete Traceability: Each indicator label carries reference (REF), lot (LOT), and expiry (EXP) information to support accurate documentation and retrospective tracking.

International Standard: Designed for use in ISO 11138-aligned sterilization monitoring and quality assurance programs.

Technical Information

SteriVision Dry Heat Biological Indicator
Product Code (Model)SVDHBI48H
Biological OrganismBacillus atrophaeus (ATCC 9372)
Incubation Time48 hours
Applicable StandardISO 11138

Product Note: Safe for its intended use when handled in accordance with the instructions for use and applicable EC requirements.

Construction and Practical Advantages

Highly Resistant Spores

Bacillus atrophaeus spores, recognized for their resistance to dry heat, provide a demanding biological challenge for reliable cycle monitoring.

Activatable Glass Ampoule

The internal glass ampoule can be activated after processing to create a closed, self-contained incubation environment.

Readable Result in 48 Hours

After the prescribed incubation period, the growth medium provides a clear visual result for routine interpretation.

High-Temperature Construction

The protective outer vial is designed to withstand dry heat cycles at 160°C and above.

Intended Use: Routine microbiological monitoring of dry heat sterilization cycles to verify that processing conditions are sufficient to inactivate resistant spores.

Compatible Systems and Applications

Dry heat sterilization processes only
Dry heat ovens operating at 160°C and above
Routine sterilizer quality control and validation programs
Healthcare, surgical, laboratory, and industrial load monitoring